Hot water boiler
A hot-water boiler is a thermal‑power device that uses the heat released by fuel combustion to raise ordinary ambient‑temperature water to a specified temperature, providing heat for space heating, domestic hot water, or industrial processes. Its defining feature is that the water inside the boiler is heated and its temperature raised without undergoing a phase change to produce steam; the output is a hot‑water medium at a specific temperature and pressure.
Our company primarily manufactures WNS low-NOx gas (or oil)-fired hot-water boilers and vacuum hot-water boilers.
+Product Overview
A hot-water boiler is a thermal‑power device that uses the heat released by fuel combustion to raise ordinary ambient‑temperature water to a specified temperature, providing heat for space heating, domestic hot water, or industrial processes. Its defining feature is that the water inside the boiler is heated but does not undergo a phase change to produce steam; instead, it delivers a hot‑water medium at a controlled temperature and pressure.
Our company primarily manufactures WNS low-NOx gas (oil)-fired hot-water boilers and vacuum hot-water boilers.
1. WNS Low-Nitrogen Gas (Oil)-Fired Hot Water Boiler

(1) Schematic Diagram of the External Dimensions of the WNS Low-Nitrogen Hot-Water Boiler


(2) WNS Low-Nitrogen Gas-Fired Hot Water Boiler Parameter Table
Parameter Category\Boiler Model
WNS0.7-1.0/95/70-Q
WNS1.4-1.0/95/70-Q
WNS2.1-1.0/95/70-Q
WNS2.8-1.0/95/70-Q
WNS3.5-1.0/95/70-Q
WNS4.2-1.0/95/70-Q
WNS5.6-1.0/95/70-Q
WNS7-1.0/95/70-Q
WNS10.5-1.25/115/70-QWNS10.5-1.25/130/70-Q
WNS14-1.25/115/70-QWNS14-1.25/130/70-Q
Rated thermal power (MW)
0.7
1.4
2.1
2.8
3.5
4.2
5.6
7
10.5
14
Rated working pressure (MPa)
1
1
1
1
1
1
1
1
1.25
1.25
Rated outlet water temperature (°C)
95
95
95
95
95
95
95
95
115/130
115/130
Rated Return Water Temperature (°C)
70
70
70
70
70
70
70
70
70
70
Full water capacity (m³)
2
2.8
4.1
5.9
6.1
8
10.9
12.6
18.7
25.1
Design thermal efficiency (%)
≥95
≥95
≥95
≥95
≥96
≥96
≥96
≥96
≥96
≥96
Flue gas temperature (°C)
≤100
≤100
≤100
≤100
≤100
≤100
≤100
≤100
≤100
≤100
Design fuel
Natural gas, town gas, coal gas, coke oven gas, No. 0 light diesel oil, etc.
Maximum transport weight (t)
3.2
4.3
5.3
8.2
9
11.3
13.9
16.5
25.2
34.9
Overall dimensions – L1 × W1 × H1 (mm)
3805×1400×1730
4100×1600×1930
4705×1800×2130
5200×2050×2385
5305×2100×2440
5735×2300×2640
6315×2505×2840
7025×2605×2940
7835×2960×3285
8265×3265×3585
Overall dimensions after installation – L2 × W2 × H2 (mm)
5240×1400×2600
6030×1600×2800
6800×1800×3120
7190×2300×3550
7325×2245×3605
7750×2505×3830
8420×2705×4010
9145×2755×4010
9995×3110×4450
10900×3415×4760
Interface diameter (mm)
Drain valve
DN80
DN100
DN125
DN150
DN200
DN200
DN200
DN200
DN250
DN250
Return valve
DN80
DN100
DN125
DN150
DN200
DN200
DN200
DN200
DN250
DN250
Safety valve
DN40
DN50
DN80
2×DN50
DN80, DN50
DN80, DN50
2×DN80
2×DN80
2×DN100
DN150+DN50/2×DN100
Drain valve
DN50
DN50
DN50
DN50
DN50
DN50
DN50
DN50
DN50
DN50
(3) Example images of installations at the production site








2. Vacuum Hot-Water Boiler
A vacuum hot-water boiler is a high-efficiency hot-water boiler that creates a negative-pressure vacuum within its sealed furnace and uses the principle of phase-change heat transfer to heat circulating water. Its operating principle involves injecting a small amount of heat-transfer fluid into the furnace; under vacuum, this fluid boils at a low temperature, generating steam. The steam then contacts condensing heat-exchange tubes, where it condenses and releases heat to warm the circulating water inside the tubes. The condensed heat-transfer fluid returns to the furnace to be reheated, and the cycle repeats continuously, ensuring the hot water in the furnace’s coil is steadily heated. Conventional vacuum hot-water boilers achieve an efficiency of ≥94%; with the addition of a condenser, efficiency can reach 96%–102%.

(1) Schematic diagram of the external dimensions of a vacuum hot-water boiler

(2) Parameter Table for Vacuum Hot-Water Boilers
ZKL0.350–ZKL7.000 (94% standard type)
Parameter\Model
Unit
ZKL0.350
ZKL0.465
ZKL0.580
ZKL0.700
ZKL0.930
ZKL1.160
ZKL1.400
ZKL1.510
ZKL1.860
ZKL2.100
ZKL2.300
ZKL2.800
ZKL5.600
ZKL7.000
Rated heating capacity
10⁴ kcal/h
30
40
50
60
80
100
120
130
160
180
200
240
480
600
kW
350
465
580
700
930
1160
1400
1510
1860
2100
2300
2800
5600
7000
Heat exchanger
△t=10
°C
60/50
△t=20
°C
80/60
△t=25
°C
75/50
△t=40
°C
60/20
Applicable Fuel
Natural gas
Fuel consumption
Nm³/h
36.7
48.9
61.1
73.4
98
122.3
146.7
159.0
195.6
220.1
244.6
293.5
586.9
733.7
Thermal efficiency
%
94
Pressure-bearing heat exchanger
MPa
1.0 (2.0)
Power supply
Use power supply
—
380V × 3-phase (50Hz)
Electrical power
kw
1.5
4
4
4
4
5.5
5.5
5.5
5.5
5.5
5.5
7.5
18.5
22
Heat transfer area
ontology
m²
14.96
24.41
24.41
24.41
29.53
52.30
52.30
52.30
80.60
80.60
80.60
83.90
177.94
254.20
Hot medium water capacity
L
254.30
403.43
403.43
403.43
495.25
430.00
430.00
430.00
950.00
950.00
950.00
980.00
2443.00
3490.00
Net weight
kilogram
1230
1765
1765
1765
1910
2230
2230
2230
3750
3750
3750
3910
9500
11020
wide
W
mm
1200
1350
1350
1350
1450
1250
1250
1250
1600
1600
1600
1650
2210
2600
long
L
mm
2550
2760
2760
2760
2820
3410
3410
3410
4050
4050
4050
4120
4780
4410
High
H
mm
1600
2010
2010
2010
2010
2260
2260
2260
2600
2600
2600
2600
3300
3310
Basic dimensions
L × W
mm
2350×1400
2550×1550
2550×1550
2550×1550
2550×1650
3000×1450
3000×1450
3000×1450
3550×1800
3550×1800
3550×1800
3550×1850
4880×2310
4450×2700
Connection
Gas supply diameter
DN(mm)
50
50
50
50
50
50
50
50
50
50
50
50
65
80
Chimney diameter
Φ (mm)
220
260
260
260
300
400
400
400
500
500
500
550
650
800
ZKL0.350-ZKL2.800 (96% high-efficiency type)
Parameter\Model
Unit
ZKL0.350
ZKL0.465
ZKL0.580
ZKL0.700
ZKL0.930
ZKL1.400
ZKL1.510
ZKL1.860
ZKL2.100
ZKL2.300
ZKL2.800
Rated heating capacity
10⁴ kcal/h
30
40
50
60
80
120
130
160
180
200
240
kW
350
465
580
700
930
1400
1510
1860
2100
2300
2800
Heat exchanger
△t=10
°C
60/50
△t=20
°C
80/60
△t=25
°C
75/50
△t=40
°C
60/20
Applicable Fuel
Natural gas
Fuel consumption
Nm³/h
36.9
47.9
59.9
71.8
95.8
143.7
155.7
191.6
215.5
239.5
287.4
Thermal efficiency
%
96
Pressure-bearing heat exchanger
MPa
1.0 (2.0)
Power supply
Use power supply
—
380V × 3-phase (50Hz)
Electrical power
kw
1.5
4
4
4
4
5.5
5.5
5.5
5.5
5.5
7.5
Heat transfer area
ontology
m²
14.96
24.41
24.41
24.41
29.53
52.3
52.3
80.6
80.6
80.6
83.9
Economizer
m²
3.7
4.1
4.1
4.1
4.6
7.5
7.5
18.2
18.2
18.2
18.2
Hot medium water capacity
L
266.85
428.46
428.46
428.46
512.16
460
460
950
950
950
980
Net weight
kilogram
1390
1920
1920
1920
2070
2490
2490
4250
4250
4250
4480
wide
W
mm
1250
1400
1400
1400
1500
1300
1300
1640
1640
1640
1650
long
L
mm
2920
3160
3160
3160
3210
3780
3780
4560
4560
4560
4660
High
H
mm
1600
2010
2010
2010
2010
2260
2260
2600
2600
2600
2600
Basic dimensions
L × W
mm
2750*1400
2950*1550
2950*1550
2950*1550
2950*1650
3450*1450
3450*1450
4070*1800
4070*1800
4070*1800
4090*1850
Connection
Gas supply diameter
DN(mm)
50
50
50
50
50
50
50
50
50
50
50
Flue diameter
Φ (mm)
220
260
260
260
300
400
400
500
500
500
550
ZKL0.350-ZKL2.800 (99% high-efficiency type)
Parameter\Model
Unit
ZKL0.350
ZKL0.465
ZKL0.580
ZKL0.700
ZKL0.930
ZKL1.400
ZKL1.510
ZKL1.860
ZKL2.100
ZKL2.300
ZKL2.800
Rated heating capacity
10⁴ kcal/h
30
40
50
60
80
120
130
160
180
200
240
kW
350
465
580
700
930
1400
1510
1860
2100
2300
2800
Heat exchanger
△t=10
°C
60/50
△t=20
°C
80/60
△t=25
°C
75/50
△t=40
°C
60/20
Applicable Fuel
Natural gas
Fuel consumption
Nm³/h
34.8
46.4
58.1
69.7
92.9
139.3
150.9
185.8
209.0
232.2
278.6
Thermal efficiency
%
99
Pressure-bearing heat exchanger
MPa
1.0 (2.0)
Power supply
Use power supply
—
380V × 3-phase (50Hz)
Electrical power
kw
1.5
4
4
4
4
5.5
5.5
5.5
5.5
5.5
7.5
Heat transfer area
ontology
m²
14.96
24.41
24.41
24.41
29.53
52.3
52.3
80.6
80.6
80.6
83.9
Economizer
m²
8.4
13.9
13.9
13.9
21.1
53
53
51.2
51.2
51.2
61.5
Hot medium water capacity
L
278.17
429.12
429.12
429.12
530.51
480
480
950
950
950
980
Net weight
kilogram
1480
2090
2090
2090
2310
2720
2720
4310
4310
4310
4550
wide
W
mm
1250
1500
1500
1500
1550
1400
1400
1600
1600
1600
1650
long
L
mm
2930
3100
3100
3100
3230
3810
3810
4510
4510
4510
4630
High
H
mm
1600
2010
2010
2010
2040
2260
2260
2600
2600
2600
2600
Basic dimensions
L × W
mm
3000*1400
3200*1550
3200*1550
3200*1550
3300*1650
4000*1450
4000*1450
4710*1800
4710*1800
4710*1800
4830*1850
Connection
Gas supply diameter
DN(mm)
50
50
50
50
50
50
50
50
50
50
50
Flue diameter
Φ (mm)
220
260
260
260
300
400
400
500
500
500
550
ZKL0.350-ZKL2.800 (102% condensing type)
Parameter\Model
Unit
ZKL0.350
ZKL0.465
ZKL0.580
ZKL0.700
ZKL0.930
Rated heating capacity
10⁴ kcal/h
30
40
50
60
80
kW
350
465
580
700
930
Applicable Fuel
Natural gas
Fuel consumption
Nm³/h
33.8
45.1
56.3
67.6
90.2
Thermal efficiency
%
102
Pressure-bearing heat exchanger
MPa
1.0 (2.0)
Power supply
Use power supply
—
380V × 3-phase (50Hz)
Electrical power
kw
1.5
4
4
4
4
Heat transfer area
ontology
m²
14.96
24.41
24.41
24.41
29.53
Condenser
m²
11.8
19.5
19.5
19.5
29.5
Hot medium water capacity
L
278.17
429.12
429.12
429.12
530.51
Net weight
kilogram
1530
2145
2145
2145
2390
wide
W
mm
1250
1500
1500
1500
1550
long
L
mm
2930
3130
3130
3130
3230
High
H
mm
1600
2010
2010
2010
2010
Basic dimensions
L × W
mm
3000*1400
3200*1550
3200*1550
3200*1550
3300*1650
Connection
Gas supply diameter
DN(mm)
50
50
50
50
50
Flue diameter
Φ (mm)
220
260
260
260
300
(3) Example images of installations at the production site



Recommended Products
Diesel generator set waste heat boiler
Design, manufacturing, and installation of waste-heat boilers for diesel generators
Waste Heat Boiler for a Galvanized Steel Pipe Plant
The waste‑heat boiler used in galvanized steel pipe plants utilizes the waste‑heat flue gases generated by the zinc‑melting furnace; after being recovered in the waste‑heat boiler, these gases are discharged. The flue gases pass through the superheater, the boiler body, and the economizer before being released into the atmosphere.
Heat-transfer edible oil heating furnace for food processing plants
The burner heats the heating surfaces inside the furnace, raising the temperature of the edible oil circulating within these surfaces to the required processing temperature, after which the oil is recirculated into the food‑oil pot to heat the food.
A steam boiler is a mechanical device that uses fuel or thermal energy to heat water into steam. It consists of the boiler proper, auxiliary equipment, and safety devices. Steam boilers are widely used in industrial and agricultural production as well as in everyday life.
A hot-water boiler is a thermal‑power device that uses the heat released by fuel combustion to raise ordinary ambient‑temperature water to a specified temperature, providing heat for space heating, domestic hot water, or industrial processes.
An organic heat carrier boiler (thermal oil furnace) is an industrial boiler that uses thermal oil as the heat transfer medium, transferring heat by heating the thermal oil.
The Q5530AE rubber cutting machine was designed by our company through years of providing equipment solutions to polymer manufacturers. It is a specialized machine tailored for the crushing, blending, and extrusion‑pelletizing of solid rubber.
Pressure vessels, chemical equipment
Our company holds design and manufacturing qualifications for medium- and low-pressure vessels, enabling us to design and produce a wide range of pressure vessels, including storage tanks, heat exchangers, agitators, reaction vessels (reactors), equipment for the production of electronic gases, and machinery for viscose fiber production lines, among others.
On-site fabrication of large storage tanks
Large storage tanks refer to vertical cylindrical steel tanks with a design capacity of no less than 1,000 cubic meters, used for storing crude oil, refined petroleum products, chemical feedstocks, and solid materials. Such tanks are fabricated on-site at the installation location.
A spiral plate heat exchanger is a high-efficiency heat transfer device whose heat-transfer elements consist of spiral-shaped plates. It is typically fabricated by rolling two parallel metal plates into a spiral configuration, thereby forming two uniform spiral channels. The two heat-transfer fluids flow through these channels and exchange heat across the spiral plate walls.
Do you have any questions? Feel free to contact us.
Follow us
Foshan Tenghui Boiler Manufacturing Co., Ltd.
Contact Us
Phone: +86-757-86255766
Email: boiler@fs-boiler.com
Address: Factory Building, Chaodongxia Shi, Zao Miao Subdistrict, Chancheng District, Foshan City
Factory Address: Tantou Industrial Zone, Diebei, Guicheng, Nanhai District, Foshan City
Quick Links
Copyright © 2026 Foshan Tenghui Boiler Manufacturing Co., Ltd.
中企跨境-全域组件 2.0.3 制作前进入CSS配置样式Telephone:
Email:
导航下拉添加类名.active
在线客服添加返回顶部
右侧在线客服样式 1,2,3 1
图片alt标题设置: Tenghui
表单验证提示文本: Content cannot be empty!
循环体没有内容时: Sorry, no matching items were found.
CSS / JS 文件放置地
SAF Coolest v1.3.1.2 设置面板 GAGSE-ZGYF-JQZDE-ZFXV1.3.1 SVG图标库请自行添加图标,用div包起来,并命名使用