Hot water boiler

A hot-water boiler is a thermal‑power device that uses the heat released by fuel combustion to raise ordinary ambient‑temperature water to a specified temperature, providing heat for space heating, domestic hot water, or industrial processes. Its defining feature is that the water inside the boiler is heated and its temperature raised without undergoing a phase change to produce steam; the output is a hot‑water medium at a specific temperature and pressure.

 

Our company primarily manufactures WNS low-NOx gas (or oil)-fired hot-water boilers and vacuum hot-water boilers.

Hot water boiler
Hot water boiler
Hot water boiler
Hot water boiler
Hot water boiler
Hot water boiler
Hot water boiler
Hot water boiler
+
  • Hot water boiler
  • Hot water boiler
  • Hot water boiler
  • Hot water boiler
  • Hot water boiler
  • Hot water boiler
  • Hot water boiler
  • Hot water boiler

Product Overview

A hot-water boiler is a thermal‑power device that uses the heat released by fuel combustion to raise ordinary ambient‑temperature water to a specified temperature, providing heat for space heating, domestic hot water, or industrial processes. Its defining feature is that the water inside the boiler is heated but does not undergo a phase change to produce steam; instead, it delivers a hot‑water medium at a controlled temperature and pressure.

 

Our company primarily manufactures WNS low-NOx gas (oil)-fired hot-water boilers and vacuum hot-water boilers.

 

1. WNS Low-Nitrogen Gas (Oil)-Fired Hot Water Boiler

 

(1) Schematic Diagram of the External Dimensions of the WNS Low-Nitrogen Hot-Water Boiler

 

(2) WNS Low-Nitrogen Gas-Fired Hot Water Boiler Parameter Table

Parameter Category\Boiler Model

WNS0.7-1.0/95/70-Q

WNS1.4-1.0/95/70-Q

WNS2.1-1.0/95/70-Q

WNS2.8-1.0/95/70-Q

WNS3.5-1.0/95/70-Q

WNS4.2-1.0/95/70-Q

WNS5.6-1.0/95/70-Q

WNS7-1.0/95/70-Q

WNS10.5-1.25/115/70-QWNS10.5-1.25/130/70-Q

WNS14-1.25/115/70-QWNS14-1.25/130/70-Q

Rated thermal power (MW)

0.7

1.4

2.1

2.8

3.5

4.2

5.6

7

10.5

14

Rated working pressure (MPa)

1

1

1

1

1

1

1

1

1.25

1.25

Rated outlet water temperature (°C)

95

95

95

95

95

95

95

95

115/130

115/130

Rated Return Water Temperature (°C)

70

70

70

70

70

70

70

70

70

70

Full water capacity (m³)

2

2.8

4.1

5.9

6.1

8

10.9

12.6

18.7

25.1

Design thermal efficiency (%)

≥95

≥95

≥95

≥95

≥96

≥96

≥96

≥96

≥96

≥96

Flue gas temperature (°C)

≤100

≤100

≤100

≤100

≤100

≤100

≤100

≤100

≤100

≤100

Design fuel

Natural gas, town gas, coal gas, coke oven gas, No. 0 light diesel oil, etc.

Maximum transport weight (t)

3.2

4.3

5.3

8.2

9

11.3

13.9

16.5

25.2

34.9

Overall dimensions – L1 × W1 × H1 (mm)

3805×1400×1730

4100×1600×1930

4705×1800×2130

5200×2050×2385

5305×2100×2440

5735×2300×2640

6315×2505×2840

7025×2605×2940

7835×2960×3285

8265×3265×3585

Overall dimensions after installation – L2 × W2 × H2 (mm)

5240×1400×2600

6030×1600×2800

6800×1800×3120

7190×2300×3550

7325×2245×3605

7750×2505×3830

8420×2705×4010

9145×2755×4010

9995×3110×4450

10900×3415×4760

Interface diameter (mm)

Drain valve

DN80

DN100

DN125

DN150

DN200

DN200

DN200

DN200

DN250

DN250

Return valve

DN80

DN100

DN125

DN150

DN200

DN200

DN200

DN200

DN250

DN250

Safety valve

DN40

DN50

DN80

2×DN50

DN80, DN50

DN80, DN50

2×DN80

2×DN80

2×DN100

DN150+DN50/2×DN100

Drain valve

DN50

DN50

DN50

DN50

DN50

DN50

DN50

DN50

DN50

DN50

 

(3) Example images of installations at the production site

 

2. Vacuum Hot-Water Boiler

A vacuum hot-water boiler is a high-efficiency hot-water boiler that creates a negative-pressure vacuum within its sealed furnace and uses the principle of phase-change heat transfer to heat circulating water. Its operating principle involves injecting a small amount of heat-transfer fluid into the furnace; under vacuum, this fluid boils at a low temperature, generating steam. The steam then contacts condensing heat-exchange tubes, where it condenses and releases heat to warm the circulating water inside the tubes. The condensed heat-transfer fluid returns to the furnace to be reheated, and the cycle repeats continuously, ensuring the hot water in the furnace’s coil is steadily heated. Conventional vacuum hot-water boilers achieve an efficiency of ≥94%; with the addition of a condenser, efficiency can reach 96%–102%.

 

(1) Schematic diagram of the external dimensions of a vacuum hot-water boiler

 

(2) Parameter Table for Vacuum Hot-Water Boilers

ZKL0.350–ZKL7.000 (94% standard type)

Parameter\Model

Unit

ZKL0.350

ZKL0.465

ZKL0.580

ZKL0.700

ZKL0.930

ZKL1.160

ZKL1.400

ZKL1.510

ZKL1.860

ZKL2.100

ZKL2.300

ZKL2.800

ZKL5.600

ZKL7.000

Rated heating capacity

10⁴ kcal/h

30

40

50

60

80

100

120

130

160

180

200

240

480

600

kW

350

465

580

700

930

1160

1400

1510

1860

2100

2300

2800

5600

7000

Heat exchanger

△t=10

°C

60/50

△t=20

°C

80/60

△t=25

°C

75/50

△t=40

°C

60/20

Applicable Fuel

 

Natural gas

Fuel consumption

Nm³/h

36.7

48.9

61.1

73.4

98

122.3

146.7

159.0

195.6

220.1

244.6

293.5

586.9

733.7

Thermal efficiency

%

94

Pressure-bearing heat exchanger

MPa

1.0 (2.0)

Power supply

Use power supply

—

380V × 3-phase (50Hz)

Electrical power

kw

1.5

4

4

4

4

5.5

5.5

5.5

5.5

5.5

5.5

7.5

18.5

22

Heat transfer area

ontology

m²

14.96

24.41

24.41

24.41

29.53

52.30

52.30

52.30

80.60

80.60

80.60

83.90

177.94

254.20

Hot medium water capacity

L

254.30

403.43

403.43

403.43

495.25

430.00

430.00

430.00

950.00

950.00

950.00

980.00

2443.00

3490.00

Net weight

kilogram

1230

1765

1765

1765

1910

2230

2230

2230

3750

3750

3750

3910

9500

11020

wide

W

mm

1200

1350

1350

1350

1450

1250

1250

1250

1600

1600

1600

1650

2210

2600

long

L

mm

2550

2760

2760

2760

2820

3410

3410

3410

4050

4050

4050

4120

4780

4410

High

H

mm

1600

2010

2010

2010

2010

2260

2260

2260

2600

2600

2600

2600

3300

3310

Basic dimensions

L × W

mm

2350×1400

2550×1550

2550×1550

2550×1550

2550×1650

3000×1450

3000×1450

3000×1450

3550×1800

3550×1800

3550×1800

3550×1850

4880×2310

4450×2700

Connection

Gas supply diameter

DN(mm)

50

50

50

50

50

50

50

50

50

50

50

50

65

80

Chimney diameter

Φ (mm)

220

260

260

260

300

400

400

400

500

500

500

550

650

800

 

ZKL0.350-ZKL2.800 (96% high-efficiency type)

Parameter\Model

Unit

ZKL0.350

ZKL0.465

ZKL0.580

ZKL0.700

ZKL0.930

ZKL1.400

ZKL1.510

ZKL1.860

ZKL2.100

ZKL2.300

ZKL2.800

Rated heating capacity

10⁴ kcal/h

30

40

50

60

80

120

130

160

180

200

240

kW

350

465

580

700

930

1400

1510

1860

2100

2300

2800

Heat exchanger

△t=10

°C

60/50

△t=20

°C

80/60

△t=25

°C

75/50

△t=40

°C

60/20

Applicable Fuel

 

Natural gas

Fuel consumption

Nm³/h

36.9

47.9

59.9

71.8

95.8

143.7

155.7

191.6

215.5

239.5

287.4

Thermal efficiency

%

96

Pressure-bearing heat exchanger

MPa

1.0 (2.0)

Power supply

Use power supply

—

380V × 3-phase (50Hz)

Electrical power

kw

1.5

4

4

4

4

5.5

5.5

5.5

5.5

5.5

7.5

Heat transfer area

ontology

m²

14.96

24.41

24.41

24.41

29.53

52.3

52.3

80.6

80.6

80.6

83.9

Economizer

m²

3.7

4.1

4.1

4.1

4.6

7.5

7.5

18.2

18.2

18.2

18.2

Hot medium water capacity

L

266.85

428.46

428.46

428.46

512.16

460

460

950

950

950

980

Net weight

kilogram

1390

1920

1920

1920

2070

2490

2490

4250

4250

4250

4480

wide

W

mm

1250

1400

1400

1400

1500

1300

1300

1640

1640

1640

1650

long

L

mm

2920

3160

3160

3160

3210

3780

3780

4560

4560

4560

4660

High

H

mm

1600

2010

2010

2010

2010

2260

2260

2600

2600

2600

2600

Basic dimensions

L × W

mm

2750*1400

2950*1550

2950*1550

2950*1550

2950*1650

3450*1450

3450*1450

4070*1800

4070*1800

4070*1800

4090*1850

Connection

Gas supply diameter

DN(mm)

50

50

50

50

50

50

50

50

50

50

50

Flue diameter

Φ (mm)

220

260

260

260

300

400

400

500

500

500

550

 

ZKL0.350-ZKL2.800 (99% high-efficiency type)

Parameter\Model

Unit

ZKL0.350

ZKL0.465

ZKL0.580

ZKL0.700

ZKL0.930

ZKL1.400

ZKL1.510

ZKL1.860

ZKL2.100

ZKL2.300

ZKL2.800

Rated heating capacity

10⁴ kcal/h

30

40

50

60

80

120

130

160

180

200

240

kW

350

465

580

700

930

1400

1510

1860

2100

2300

2800

Heat exchanger

△t=10

°C

60/50

△t=20

°C

80/60

△t=25

°C

75/50

△t=40

°C

60/20

Applicable Fuel

 

Natural gas

Fuel consumption

Nm³/h

34.8

46.4

58.1

69.7

92.9

139.3

150.9

185.8

209.0

232.2

278.6

Thermal efficiency

%

99

Pressure-bearing heat exchanger

MPa

1.0 (2.0)

Power supply

Use power supply

—

380V × 3-phase (50Hz)

Electrical power

kw

1.5

4

4

4

4

5.5

5.5

5.5

5.5

5.5

7.5

Heat transfer area

ontology

m²

14.96

24.41

24.41

24.41

29.53

52.3

52.3

80.6

80.6

80.6

83.9

Economizer

m²

8.4

13.9

13.9

13.9

21.1

53

53

51.2

51.2

51.2

61.5

Hot medium water capacity

L

278.17

429.12

429.12

429.12

530.51

480

480

950

950

950

980

Net weight

kilogram

1480

2090

2090

2090

2310

2720

2720

4310

4310

4310

4550

wide

W

mm

1250

1500

1500

1500

1550

1400

1400

1600

1600

1600

1650

long

L

mm

2930

3100

3100

3100

3230

3810

3810

4510

4510

4510

4630

High

H

mm

1600

2010

2010

2010

2040

2260

2260

2600

2600

2600

2600

Basic dimensions

L × W

mm

3000*1400

3200*1550

3200*1550

3200*1550

3300*1650

4000*1450

4000*1450

4710*1800

4710*1800

4710*1800

4830*1850

Connection

Gas supply diameter

DN(mm)

50

50

50

50

50

50

50

50

50

50

50

Flue diameter

Φ (mm)

220

260

260

260

300

400

400

500

500

500

550

 

ZKL0.350-ZKL2.800 (102% condensing type)

Parameter\Model

Unit

ZKL0.350

ZKL0.465

ZKL0.580

ZKL0.700

ZKL0.930

Rated heating capacity

10⁴ kcal/h

30

40

50

60

80

kW

350

465

580

700

930

Applicable Fuel

 

Natural gas

Fuel consumption

Nm³/h

33.8

45.1

56.3

67.6

90.2

Thermal efficiency

%

102

Pressure-bearing heat exchanger

MPa

1.0 (2.0)

Power supply

Use power supply

—

380V × 3-phase (50Hz)

Electrical power

kw

1.5

4

4

4

4

Heat transfer area

ontology

m²

14.96

24.41

24.41

24.41

29.53

Condenser

m²

11.8

19.5

19.5

19.5

29.5

Hot medium water capacity

L

278.17

429.12

429.12

429.12

530.51

Net weight

kilogram

1530

2145

2145

2145

2390

wide

W

mm

1250

1500

1500

1500

1550

long

L

mm

2930

3130

3130

3130

3230

High

H

mm

1600

2010

2010

2010

2010

Basic dimensions

L × W

mm

3000*1400

3200*1550

3200*1550

3200*1550

3300*1650

Connection

Gas supply diameter

DN(mm)

50

50

50

50

50

Flue diameter

Φ (mm)

220

260

260

260

300

 

(3) Example images of installations at the production site

 

Recommended Products

Diesel generator set waste heat boiler

Design, manufacturing, and installation of waste-heat boilers for diesel generators

Waste Heat Boiler for a Galvanized Steel Pipe Plant

The waste‑heat boiler used in galvanized steel pipe plants utilizes the waste‑heat flue gases generated by the zinc‑melting furnace; after being recovered in the waste‑heat boiler, these gases are discharged. The flue gases pass through the superheater, the boiler body, and the economizer before being released into the atmosphere.

Heat-transfer edible oil heating furnace for food processing plants

The burner heats the heating surfaces inside the furnace, raising the temperature of the edible oil circulating within these surfaces to the required processing temperature, after which the oil is recirculated into the food‑oil pot to heat the food.

Steam boiler

A steam boiler is a mechanical device that uses fuel or thermal energy to heat water into steam. It consists of the boiler proper, auxiliary equipment, and safety devices. Steam boilers are widely used in industrial and agricultural production as well as in everyday life.

Hot water boiler

A hot-water boiler is a thermal‑power device that uses the heat released by fuel combustion to raise ordinary ambient‑temperature water to a specified temperature, providing heat for space heating, domestic hot water, or industrial processes.

Organic Heat Transfer Boiler

An organic heat carrier boiler (thermal oil furnace) is an industrial boiler that uses thermal oil as the heat transfer medium, transferring heat by heating the thermal oil.

Polymer gel cutting machine

The Q5530AE rubber cutting machine was designed by our company through years of providing equipment solutions to polymer manufacturers. It is a specialized machine tailored for the crushing, blending, and extrusion‑pelletizing of solid rubber.

Pressure vessels, chemical equipment

Our company holds design and manufacturing qualifications for medium- and low-pressure vessels, enabling us to design and produce a wide range of pressure vessels, including storage tanks, heat exchangers, agitators, reaction vessels (reactors), equipment for the production of electronic gases, and machinery for viscose fiber production lines, among others.

On-site fabrication of large storage tanks

Large storage tanks refer to vertical cylindrical steel tanks with a design capacity of no less than 1,000 cubic meters, used for storing crude oil, refined petroleum products, chemical feedstocks, and solid materials. Such tanks are fabricated on-site at the installation location.

Spiral plate heat exchanger

A spiral plate heat exchanger is a high-efficiency heat transfer device whose heat-transfer elements consist of spiral-shaped plates. It is typically fabricated by rolling two parallel metal plates into a spiral configuration, thereby forming two uniform spiral channels. The two heat-transfer fluids flow through these channels and exchange heat across the spiral plate walls.

Do you have any questions? Feel free to contact us.

%{tishi_zhanwei}%

SAF Coolest v1.3.1.2 设置面板GAGSE-ZGYF-JQZDE-ZFX

V1.3.1 SVG图标库请自行添加图标,用div包起来,并命名使用

Do you have any questions? Feel free to contact us.

We can recommend suitable products based on your needs.